Customization: | Available |
---|---|
After-sales Service: | 24/7 Online After Sales Services |
Warranty: | 12 Months After Delivery Date |
Still deciding? Get samples of US$ 450/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
Our unwavering commitment is to deliver your ordered product at the earliest possible date, precisely meeting your requirements. We ensure timely and efficient service that exceeds expectations.The installation of the electromagnetic flowmeter is tailored to match the specific site pipeline conditions. For pipelines without pressure, flowmeters that do not incorporate a ball valve are suitable. This selection is ideal for non-pressurized installations, offering simplicity and efficacy.
A precise 50mm diameter hole must be created in the pipeline, followed by welding a connecting pipe to the newly established opening. This ensures a seamless integration of the flowmeter.
In scenarios demanding uninterrupted flow during loading and unloading or where media spillage is unacceptable, incorporating a ball valve is essential. Opt for an insertion-type electromagnetic flowmeter with a ball valve structure to meet these needs efficiently.
Again, a 50mm diameter hole is necessary in the pipeline. Prepare to weld a connecting pipe to the opening, ensuring a robust and secure installation.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
To achieve optimal performance, the piping must have straight sections of 5D upstream and 3D downstream. This configuration ensures the electromagnetic flowmeter operates correctly and meets stringent accuracy standards.
The electromagnetic flowmeter's measurement principle is independent of the flow characteristics, ensuring consistent and reliable performance.
Even if turbulence and vortices are present in the non-measurement area (caused by elbows, tangential throttling, or partially open shut-off valves upstream), they do not impact measurement accuracy.
Conversely, steady-state vortices within the measurement area can compromise both stability and accuracy. It is crucial to address this to maintain the integrity of measurements.
When encountering such issues, consider implementing the following measures to stabilize the flow distribution:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To counteract the effects of vortices and flow field distortion, it's crucial to adhere to specific lengths for the upstream and downstream straight pipe sections. This practice ensures precise measurement accuracy (a straightener can also be used, and avoid placing the flowmeter near control valves and partially open valves).
2.2. Requirements for the Process Pipes The upstream and downstream process pipes at the installation point must meet specific criteria to maintain measurement accuracy. a. The inner diameter of these pipes should match the sensor's inner diameter, adhering to the condition: 0.98DN ≤ D ≤ 1.05DN (DN represents the sensor's inner diameter, and D is the inner diameter of the process pipe). b. The process pipe and sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance of the flowmeter, incorporating a bypass pipe is highly recommended. This becomes essential for heavily contaminated fluids or scenarios where you need to clean the flowmeter without interrupting the fluid flow. a. Facilitates convenient maintenance of the flowmeter. b. Essential for handling heavily contaminated fluids. c. Enables cleaning without halting the fluid flow.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections Inlet/Outlet Straight Pipe Sections: The inlet should be at least 10 times the diameter (≥ 10×DN) and the outlet should be at least 5 times the diameter (≥ 5×DN).
3.2. Requirements for Grounding Points To guarantee consistent and accurate measurement, the instrument must be shielded from external parasitic potentials. Ensure the sensor is properly grounded, with a grounding resistance less than 10 ohms. (A dedicated grounding device is unnecessary if the metal pipeline is well-grounded.)
3.3. Requirements for Installation Position Refer to the provided diagram for detailed installation positioning.
COMPANY AND FACTORY PICTURES: