Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
We are committed to delivering your ordered product at the earliest date as per your requirements, ensuring timely and efficient service. Our streamlined logistics and meticulous packing protocols guarantee that your High Accuracy Electromagnetic Flowmeter with 100ms Response Time and IP67 rating arrives safely and promptly. Trust in Shandong Zhongziyi Intelligent Technology Co., Ltd. for reliable and fast delivery.To ensure seamless installation of the electromagnetic flowmeter, it is crucial to consider the site pipeline conditions. When selecting a flowmeter without a ball valve, installation should occur on a non-pressurized pipeline.
Prepare the pipeline by creating a 50mm diameter hole and weld a connecting pipe to the opening, ensuring a robust and secure connection.
For continuous flow scenarios or where media overflow is prohibitive, an insertion-type electromagnetic flowmeter with a ball valve structure is essential.
Similarly, for insertion-type flowmeters, create a 50mm diameter hole in the pipeline and weld a connecting pipe to the opening for optimal installation.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
Adherence to the straight pipe section requirements-5D upstream and 3D downstream-is vital to ensure the electromagnetic flowmeter operates accurately.
The electromagnetic flowmeter's measurement principle remains unaffected by flow characteristics.
Turbulence and vortices in non-measurement areas, such as those caused by elbows or partially open valves, will not impact measurement accuracy.
However, steady-state vortices within the measurement area can compromise measurement stability and accuracy.
In such cases, measures to stabilize the flow distribution should be considered:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To maintain measurement accuracy, adhere to specific lengths for upstream and downstream straight pipe sections to mitigate vortices and flow distortion. Installing a straightener and avoiding proximity to control valves is also advisable.
2.2. Requirements for Process Pipes Ensure the upstream and downstream process pipes match the sensor's inner diameter (0.98DN ≤ D ≤ 1.05DN) and are concentric with an axial deviation of no more than 0.05DN for precise measurements.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance and optimal performance of the flowmeter, it is highly recommended to install a bypass pipe. This is particularly crucial for fluids with heavy contamination or in scenarios where cleaning the flowmeter without halting the fluid flow is necessary. Key points include: a. Facilitating easy maintenance of the flowmeter. b. Essential installation for heavily contaminated fluids. c. Enables flowmeter cleaning without interrupting fluid flow.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections To maintain accurate measurements, specific straight pipe sections are required. The inlet pipe section should be at least 10 times the diameter of the nominal pipe size (≥ 10×DN), while the outlet pipe section should be at least 5 times the diameter of the nominal pipe size (≥ 5×DN).
3.2. Requirements for Grounding Points For ensuring the reliable operation and high measurement accuracy of the instrument, it is imperative to avoid external parasitic potentials. The sensor must be well-grounded, with grounding resistance kept below 10 ohms. Note: If the metal pipeline is already well-grounded, a dedicated grounding device is not necessary.
3.3. Installation Position Requirements Please refer to the accompanying diagram for detailed installation position requirements.