Customization: | Available |
---|---|
After-sales Service: | 24/7 Online After Sales Services |
Warranty: | 12 Months After Delivery Date |
Still deciding? Get samples of US$ 450/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
We are dedicated to ensuring that your ordered High Accuracy Flowmeter with 4-20mA Output and Anti-Vibration Technology is delivered promptly and precisely as per your specifications. Our commitment to timely and efficient service guarantees that your needs are met with the utmost reliability and professionalism.The installation of the electromagnetic flowmeter depends on the specific site pipeline conditions. For non-pressurized pipelines, where a ball valve isn't required, you may choose a flowmeter model without a ball valve, simplifying the installation process.
Create a 50mm diameter hole in the pipeline and prepare to weld a connecting pipe to this opening for secure attachment.
In scenarios requiring continuous flow during operations or where media overflow is unacceptable, incorporating a ball valve is essential. This necessitates selecting an insertion-type electromagnetic flowmeter with a ball valve structure for precise control.
Create a 50mm diameter hole in the pipeline and prepare to weld a connecting pipe to this opening, ensuring a robust and secure connection.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
To ensure optimal performance and accuracy, the straight pipe sections should be 5D upstream and 3D downstream of the electromagnetic flowmeter.
The electromagnetic flowmeter's measurement principle is independent of the flow characteristics, providing reliable readings under various conditions.
Even if turbulence and vortices occur in the non-measurement areas of the pipeline (such as due to elbows, tangential throttling, or partially open shut-off valves upstream), the measurement accuracy remains unaffected.
However, steady-state vortices within the measurement area can impact both the stability and accuracy of the readings.
In such cases, measures should be taken to stabilize the flow distribution, including the following:
1.2. Pipeline-type electromagnetic flowmeter
2.1. Requirements for straight sections To reduce the impact of vortices and flow field distortion, adhere to specific requirements for the lengths of the straight pipe sections upstream and downstream of the flowmeter. This ensures measurement accuracy and it is advisable to avoid installation close to control valves and partially open valves. A straightener can also be installed if needed.
2.2. Requirements for process pipes The flowmeter has specific requirements for the upstream and downstream process pipes at the installation point. a. The inner diameters of the upstream and downstream process pipes should match that of the sensor, meeting the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter, and D is the process pipe's inner diameter). b. The process pipe and the sensor must be concentric, with an axial deviation not exceeding 0.05DN to ensure accurate measurement.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance of your high-accuracy flowmeter, it is highly recommended to install a bypass pipe. This is especially critical for scenarios involving heavily contaminated fluids or situations that necessitate cleaning the flowmeter without halting fluid flow. a. Facilitates maintenance of the flowmeter. b. Essential for heavily contaminated fluids. c. Enables cleaning of the flowmeter without stopping fluid flow.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections Ensure optimal performance with precise placement of inlet and outlet straight pipe sections: Inlet should be ≥ 10×DN; Outlet should be ≥ 5×DN.
3.2. Requirements for Grounding Points To guarantee reliable operation and enhance measurement accuracy of the instrument, it is imperative to safeguard it from external parasitic potentials. The sensor must be properly grounded with a grounding resistance below 10 ohms. (If the metal pipeline is already well-grounded, a dedicated grounding device is not necessary.)
3.3. Installation Position Requirements Refer to the accompanying diagram for detailed installation positioning.
COMPANY AND FACTORY PICTURE: