Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
At Shandong Zhongziyi Intelligent Technology Co., Ltd., we pride ourselves on our commitment to excellence. We ensure that your Wireless Transmission Electromagnetic Flowmeter with High Precision and Reliability is delivered promptly, aligning perfectly with your specified requirements. Our goal is to provide you with a timely and efficient service that exceeds your expectations.The installation of the electromagnetic flowmeter varies depending on the site pipeline conditions. For flowmeters without a ball valve, they should be installed on a non-pressurized pipeline. This allows for a straightforward installation since non-pressurized pipelines enable the selection of flowmeters without the need for a ball valve.
A hole with a diameter of 50mm should be carefully made in the pipeline. Ensure that preparations are in place to weld a connecting pipe securely to the opening.
For scenarios that demand continuous flow during loading and unloading, or where media overflow must be avoided, incorporating a ball valve is essential. This necessitates the selection of an insertion-type electromagnetic flowmeter with a ball valve structure.
Again, create a hole with a diameter of 50mm in the pipeline and make necessary arrangements to weld a connecting pipe to the opening.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
The installation requires specific straight pipe sections: 5D upstream and 3D downstream. Adhering to these specifications ensures the optimal performance and accuracy of the electromagnetic flowmeter.
The measurement principle of the electromagnetic flowmeter is independent of the flow characteristics. This robust principle ensures accurate readings even under varying conditions.
If turbulence and vortices are generated in the non-measurement area of the pipeline (such as near elbows, tangential throttling, or a partially open shut-off valve upstream), it will not impact the measurement performance.
However, steady-state vortices within the measurement area can compromise both stability and accuracy.
In such instances, measures should be taken to stabilize the flow distribution:
1.2. Pipeline-type electromagnetic flowmeter
2.1. Requirements for straight sections To mitigate the effects of vortices and flow field distortion, specific lengths for the straight pipe sections upstream and downstream of the flowmeter are essential. Otherwise, measurement accuracy will be compromised. Installing a straightener is advisable, and avoid placing the flowmeter close to control valves or partially open valves.
2.2. Requirements for the process pipes The flowmeter has critical requirements for the upstream and downstream process pipes at the installation point to ensure measurement accuracy. a. The inner diameter of the upstream and downstream process pipes should match the sensor's diameter and meet the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter, and D is the process pipe's inner diameter). b. The process pipe and the sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes: To ensure seamless maintenance of the flowmeter, installing a bypass pipe is highly recommended. For fluids with heavy contamination, or when cleaning the flowmeter without halting fluid flow, a bypass pipe is essential. a. Facilitates maintenance of the flowmeter. b. Mandatory for heavily contaminated fluids. c. Allows cleaning of the flowmeter without stopping fluid flow.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters: Precise installation is crucial for optimal performance and accuracy.
3.1. Requirements for Straight Pipe Sections: Ensure inlet/outlet straight pipe sections comply with the following: Inlet should be ≥ 10×DN; Outlet should be ≥ 5×DN for optimal flow accuracy and stability.
3.2. Requirements for Grounding Points: To guarantee reliable instrument operation and enhanced measurement precision, minimize the influence of external parasitic potentials. Ensure the sensor has excellent grounding, with grounding resistance below 10. (If the metal pipeline is adequately grounded, a separate grounding device is unnecessary.)
3.3. Requirements for Installation Position: Refer to the accompanying diagram for precise installation positioning.
COMPANY AND FACTORY PICTURE: A visual representation of Shandong Zhongziyi Intelligent Technology Co., Ltd. and its state-of-the-art facilities.