Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
At Shandong Zhongziyi Intelligent Technology Co., Ltd., we are dedicated to ensuring that your ordered IP67 Electromagnetic Flowmeter with High Precision and Threaded Mounting Options is delivered promptly and efficiently. We understand the importance of timely and reliable service, and we strive to meet your requirements with the utmost precision and care.The installation of the IP67 Electromagnetic Flowmeter with High Precision and Threaded Mounting Options by Shandong Zhongziyi Intelligent Technology Co., Ltd. varies based on the site pipeline conditions. Flowmeters that are not equipped with a ball valve must be installed on non-pressurized pipelines, ensuring a seamless and efficient setup.
A precisely cut hole with a diameter of 50 mm should be made in the pipeline. Preparations must include welding a connecting pipe to this opening to ensure a secure installation.
For applications that necessitate uninterrupted flow during loading/unloading or where media overflow is strictly prohibited, a ball valve is essential. This mandates the selection of an insertion-type electromagnetic flowmeter featuring a ball valve structure.
A 50 mm diameter hole should be made in the pipeline, followed by welding a connecting pipe to the opening. This ensures a robust and leak-proof connection.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
The straight pipe requirements are 5 times the diameter (5D) upstream and 3 times the diameter (3D) downstream. This configuration guarantees the optimal performance and accuracy of the electromagnetic flowmeter.
The measurement principle of the electromagnetic flowmeter is independent of the flow characteristics, making it a versatile and reliable choice.
If turbulence and vortices are created in the non-measurement areas of the pipeline-such as near elbows, tangential throttling, or partially open shut-off valves upstream-it will not impact the measurement accuracy.
However, steady-state vortices within the measurement area can compromise both the stability and accuracy of readings.
In such cases, specific measures should be implemented to stabilize the flow distribution:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To counteract the effects of vortices and distorted flow fields, specific straight pipe lengths upstream and downstream are required. This is critical for maintaining measurement accuracy. A flow straightener can also be installed, and it is advisable to avoid positioning near control valves or partially open valves.
2.2. Requirements for Process Pipes The electromagnetic flowmeter has strict requirements for the upstream and downstream process pipes at the installation point to ensure measurement accuracy: a. The inner diameter of these pipes should match that of the sensor, complying with 0.98DN ≤ D ≤ 1.05DN (where DN is the inner diameter of the sensor, and D is the inner diameter of the process pipe). b. The process pipe and sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance of the IP67 Electromagnetic Flowmeter with High Precision and Threaded Mounting Options, installing a bypass pipe is highly recommended. This is especially crucial for applications involving heavily contaminated fluids or instances where cleaning the flowmeter without stopping the fluid flow is necessary. a. Eases the maintenance process of the flowmeter. b. Essential for handling heavily contaminated fluids. c. Facilitates cleaning of the flowmeter while maintaining uninterrupted fluid flow.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections For optimal performance of the IP67 Electromagnetic Flowmeter, adhere to the following straight pipe section requirements: Inlet straight pipe: Should be at least 10×DN; Outlet straight pipe: Should be at least 5×DN.
3.2. Requirements for Grounding Points To ensure the reliable operation and enhanced measurement accuracy of the IP67 Electromagnetic Flowmeter, it must be free from external parasitic potentials. Proper grounding of the sensor is imperative, with a grounding resistance of less than 10 ohms. (In cases where the metal pipeline is well-grounded, a dedicated grounding device is not required.)
3.3. Requirements for Installation Position Follow the diagram to correctly position the IP67 Electromagnetic Flowmeter for optimal operation.
COMPANY AND FACTORY PICTURE: