Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
We are committed to delivering your ordered product at the earliest possible date, tailored to your specific requirements. We ensure timely and efficient service, promising a swift and reliable delivery experience.The installation of the electromagnetic flowmeter by Shandong Zhongziyi Intelligent Technology Co., Ltd. varies based on the site pipeline conditions. For flowmeters without a ball valve, ensure they are installed on a non-pressurized pipeline. This installation method allows users to select flowmeters that do not require a ball valve.
Create a 50mm diameter hole in the pipeline, then prepare to weld a connecting pipe to this opening to ensure a secure fit for the flowmeter.
For installations requiring continuous flow during loading/unloading or where no media overflow is permitted, include a ball valve. This setup necessitates the use of an insertion-type electromagnetic flowmeter with a ball valve structure.
Create a 50mm diameter hole in the pipeline, then prepare to weld a connecting pipe to this opening to ensure a secure fit for the flowmeter.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
To ensure precise measurements and optimal performance, maintain straight pipe sections of 5D upstream and 3D downstream of the electromagnetic flowmeter.
The measurement principle of the electromagnetic flowmeter by Shandong Zhongziyi Intelligent Technology Co., Ltd. is independent of the flow characteristics, ensuring reliable performance.
Turbulence and vortices in non-measurement areas, such as elbows or throttling points, will not affect the accuracy of the measurements.
However, steady-state vortices within the measurement area can impact the stability and accuracy of the readings.
To counteract this, consider the following measures to stabilize flow distribution:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To mitigate the effects of vortices and flow field distortions, adhere to the specified lengths for upstream and downstream straight pipe sections. This will ensure measurement accuracy. If necessary, install a straightener and avoid proximity to control valves or partially open valves.
2.2. Requirements for the Process Pipes Ensure the upstream and downstream process pipes meet the following criteria to maintain measurement accuracy: a. The inner diameter should match that of the sensor (0.98DN ≤ D ≤ 1.05DN, where DN is the sensor's inner diameter). b. Pipes and sensors must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance of our cutting-edge High Reliability Flowmeter with IP67 Rating and 100ms Response Time, it is highly recommended to install a bypass pipe. This is crucial for scenarios involving heavily contaminated fluids and situations where cleaning the flowmeter without interrupting the fluid flow is necessary. a. Facilitates easy and timely maintenance of the flowmeter. b. Essential for handling heavily contaminated fluids. c. Enables flowmeter cleaning without halting fluid flow.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections To ensure optimal performance of the flowmeter, observe these straight pipe section guidelines: Inlet straight pipe section should be ≥ 10×DN, while the outlet straight pipe section should be ≥ 5×DN.
3.2. Grounding Point Requirements For the unwavering reliability and superior accuracy of the flowmeter, it is vital to minimize the influence of external parasitic potentials. The sensor must be well-grounded, ensuring a grounding resistance of less than 10 ohms. (Note: If the metal pipeline is already well-grounded, a dedicated grounding device is not necessary.)
3.3. Installation Position Requirements Please refer to the provided diagram for detailed installation positioning to guarantee peak functionality.
COMPANY AND FACTORY PICTURES: