Customization: | Available |
---|---|
After-sales Service: | 24/7 After Sales Services |
Warranty: | 12 Months From Delivery |
Still deciding? Get samples of US$ 400/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Comprehensive Product Overview
The ZZYS30 vortex flowmeter is an advanced, high-precision velocity flow instrument designed for diverse application needs.
Perfect for the accurate measurement, vigilant monitoring, and precise control of the flow of liquids, steam, and a wide range of gases.
Boasting a robust new structure, it is highly resistant to mechanical vibrations, impacts, and contamination, ensuring longevity and durability.
Its design eliminates moving parts, thereby preventing wear and tear, reducing mechanical maintenance needs, minimizing pressure loss, and delivering stable, high-accuracy performance.
User-friendly installation process with flexible matching options for the sensor and signal converter to meet specific requirements.
Outstanding Product Features:
Extensive application versatility, perfect for measuring the flow of steam, gas, and liquid in various industrial settings.
Superior vibration resistance, with zero drift at zero points, effectively neutralizing the impact of external vibrations for consistent accuracy.
The ZZY30 model offers integrated temperature and pressure options, significantly reducing installation costs for users.
Supports multiple output formats, including (0-5) kHz frequency output, (4-20) mA output, and HART communication/Modbus protocol communication.
Enhanced parameter setting convenience via Bluetooth communication. Wear-resistant and dirt-resistant, it requires no mechanical maintenance, boasts a long service life, and includes explosion-proof safety features.
Technical Index
Measurement Medium: Gas, Liquid, Steam
Connection Method: Flange Clamp Type, Flange Type, Insertion Type
Caliber Specifications:
Flange Clamping Type: 25mm, 32mm, 50mm, 80mm, 100mm.
Flange Connection Type Caliber Selection: 100mm, 150mm, 200mm
Flow Measurement Range: Normal measurement flow velocity range: Reynolds number 1.5×104~4×106; Gas: 5~50m/s; Liquid: 0.5~7m/s.
Normal Measurement Flow Range: Liquid,
Gas Flow Measurement Range: See Table 2.
Steam Flow Range: See Table 3.
Measurement Accuracy: Class 1.0, Class 1.5
Measured Medium Temperature:
Room Temperature: -25ºC~100ºC; High Temperature: -25ºC~150ºC, -25ºC~250ºC Output Signal: Pulse voltage output signal, High level 8~10V, Low level 0.7~1.3V. Pulse duty cycle is about 50%, transmission distance is 100m
Pulse Current Remote Transmission Signal: 4-20 mA, transmission distance is 1000m Instrument Use Environment: Temperature: -25ºC~+55ºC, Humidity: 5~90% RH at 50ºC Material: Stainless Steel, Aluminum Alloy
Power Supply: DC 24V or Lithium Battery 3.6V
Explosion-Proof Grade: Intrinsically safe iaIIbT3-T6, Protection Level IP65.
Technical parameters | |
Medium | Steam, Gas, Liquid |
Measuring range | See flow1-3 |
Caliber | DN15, DN25, DN40, DN50, DN80, DN100, DN200, DN250, DN300 |
Medium pressure | ≤100 bar, more pressure need be customized |
Medium temperature | -40°C~+240°C |
Ambient temperature | Ordinary type: -40°C~+85°C Ex-proof type: -40°C~+60°C |
Accuracy | Liquid, Re≥20000 is ±1.0%, gas and steam, ±1.5% |
Repeatability | ±0.3% |
Material | Measuring pipe:304,316L, HC276 |
Sensor: 316L, HC276 | |
Converter shell: casting aluminum | |
Instrument caliber | Flange connection: DN15-DN300 |
Clamping connection: DN15-DN100 | |
Flange standard | DIN, ANSI, HG20592 (Can be customized) |
Pressure loss Gasandliquid saturated steam |
ΔP=Cqv²Px ΔP: pressure loss(pa) qv: volume flow qm: mass flow ΔP=Cqm²Px PX: density C: constent |
Display | Two-line LCD display, four button operation Instantaneous flow, accumulated flow, vortex frequency, medium temperature, pressure(selectable), circular or non-circular display |
Power supply | Ordinary type: (14~36) VDC Ex-proof type: (14~30) VDC Battery power supply |
Loading | No-ex-proof: RB=(UB-14DVC)/22MA≤1200Ω Ex-proof: RB=(UB-14DVC)/22MA≤600Ω |
Output | Two wire 4~20mA |
Ex-proof class | Exd II CT6 CE19.1438 Ex ( ia ) II CT6 |
Cable interface | 1/2''NPT( Internal thread, recommended), M201.5 (Internal thread) |
Housing protection class | IP67 |
Connection type | Flange (DN15-DN300), Clamping (DN15-DN100) |
Mounting type | Integral mounting, split mounting (special shielded cable connect the pipe and indicator) |
Gas | |||
Air: t=20°C p=1.013bar abs =1.7210-4 mpa.s Q: flow (sheet 1) | |||
Nominal diameter | Internal diameter | Qmin(m3/h) | Qmax(m3/h) |
DN15 | 16 | 6.79 | 32.56 |
DN25 | 24 | 10.20 | 113.94 |
DN40 | 38 | 25.3 | 326.63 |
DN50 | 50 | 43.89 | 565.49 |
DN80 | 74 | 96.14 | 1238.64 |
DN100 | 97 | 165.14 | 2128.27 |
DN150 | 146 | 374.23 | 4821.57 |
DN200 | 193 | 702.95 | 9056.8 |
DN250 | 253 | 1123.7 | 14478 |
DN300 | 305 | 1632.1 | 21028 |
Liquid | |||
Water: t=20°C p=1.013bar abs ≤10cp Q: flow | |||
Nominal diameter | Internal diameter | Qmin(m3/h) | Qmax(m3/h) |
DN15 | 16 | 0.45 | 5 |
DN25 | 24 | 0.81 | 11.40 |
DN40 | 38 | 2.04 | 28.57 |
DN50 | 50 | 3.53 | 49.47 |
DN80 | 74 | 7.74 | 108.37 |
DN100 | 97 | 13.30 | 186.21 |
DN150 | 146 | 30.13 | 421.86 |
DN200 | 193 | 52.66 | 792.42 |
DN250 | 253 | 90.5 | 1266.8 |
DN300 | 305 | 113.41 | 1839.8 |
Saturated steam | |||||||||
Nominal Diameter |
Inner Diameter |
Mass flow Qm (kg/h) under different pressure and density | |||||||
P=1bar G | P=3.5bar G | P=5.2bar G | P=7 bar G | ||||||
ρ=1.13kg/m3 | ρ=2.43kg/m3 | ρ=3.28kg/m3 | ρ=4.17kg/m3 | ||||||
t=120.6°C | t=148.2°C | t=160.4°C | t=170.6°C | ||||||
min | max | min | max | min | max | min | max | ||
DN15 | 16 | 5.87 | 36.97 | 7.68 | 79 | 8.93 | 106.68 | 10.06 | 135.69 |
DN25 | 24 | 11.82 | 129.39 | 17.26 | 276.4 | 20.09 | 373.53 | 22.66 | 474.82 |
DN40 | 38 | 29.64 | 370.71 | 43.33 | 792.33 | 50.63 | 1070.2 | 56.8 | 1361.2 |
DN50 | 50 | 51.31 | 641.82 | 75.02 | 1371.8 | 87.19 | 1852.8 | 98.33 | 2356.6 |
DN80 | 74 | 112.41 | 1405.8 | 164.33 | 3004.7 | 191 | 4058.4 | 215.39 | 5161.8 |
DN100 | 97 | 193.14 | 2415.5 | 282.36 | 5162.7 | 328.16 | 6973.3 | 370.09 | 8869.2 |
DN150 | 146 | 437.56 | 5472.4 | 639.69 | 11696 | 743.45 | 15798 | 838.44 | 20093 |
DN200 | 193 | 821.91 | 10279 | 1201.6 | 21970 | 1396.5 | 29675 | 1574.9 | 37743 |
DN250 | 253 | 1313.9 | 16433 | 1920.9 | 35122 | 2232.5 | 47439 | 2517.7 | 60337 |
DN300 | 305 | 1908.3 | 23866 | 2789.8 | 51010 | 3242.4 | 68899 | 3656.6 | 87630 |
Nominal Diameter |
Inner Diameter |
Mass flow Qm (kg/h) under different pressure and density | |||||||
P=10.5 bar G | P=14 bar G | P=17.5 bar G | P=20 bar G | ||||||
ρ=5.89kg/m3 | ρ=7.6kg/m3 | ρ=9.32kg/m3 | ρ=10.54kg/m3 | ||||||
t=186.2°C | t=198.5°C | t=208.5°C | t=215.6°C | ||||||
min | max | min | max | min | max | min | max | ||
DN15 | 16 | 12.78 | 191.71 | 16.51 | 247.55 | 20.23 | 303.36 | 22.89 | 343.32 |
DN25 | 24 | 26.93 | 670.88 | 30.6 | 857.88 | 33.87 | 955.48 | 36.04 | 1201.41 |
DN40 | 38 | 67.51 | 1878.2 | 76.72 | 2150.7 | 84.93 | 2395.3 | 90.35 | 2557.7 |
DN50 | 50 | 116.89 | 3251.7 | 132.82 | 3723.4 | 147.03 | 4147 | 156.42 | 4428.1 |
DN80 | 74 | 256.03 | 7122.4 | 290.93 | 8155.8 | 322.06 | 9083.7 | 342.62 | 9699.3 |
DN100 | 97 | 439.91 | 12238 | 499.9 | 14013 | 553.38 | 15608 | 588.69 | 16666 |
DN150 | 146 | 996.62 | 27725 | 1132.5 | 31747 | 1253.7 | 35359 | 1333.7 | 37756 |
DN200 | 193 | 1872.1 | 52079 | 2127.3 | 59634 | 2354.9 | 66419 | 2505.2 | 70921 |
DN250 | 253 | 2992.7 | 83254 | 3400.71 | 95333 | 3764.6 | 106180 | 4004.9 | 113380 |
DN300 | 305 | 4346.5 | 120920 | 4939.1 | 138460 | 5467.5 | 154210 | 5816.5 | 164660 |
Selection list | ||||||||
model | Explanation | |||||||
ZZY30 | ||||||||
Connection | F | Flange connection | ||||||
W | Flange clamping | |||||||
Temperature Resistance Class |
T1 | Match with 250°c probe | ||||||
T2 | Match with 350°c probe | |||||||
Nominal diameter |
015 | DN15 | ||||||
020 | DN20 | |||||||
025 | DN25 | |||||||
032 | DN32 | |||||||
040 | DN40 | |||||||
050 | DN50 | |||||||
065 | DN65 | |||||||
080 | DN80 | |||||||
100 | DN100 | |||||||
125 | DN125 | |||||||
150 | DN150 | |||||||
200 | DN200 | |||||||
250 | DN250 | |||||||
300 | DN300 | |||||||
Structure |
Z | Integrated T and P compensation | ||||||
F | Regular model | |||||||
S | Split | |||||||
Material | R1 | 304 | ||||||
RL | 316L | |||||||
Instrument model |
N | 24V power supply Output 3 wire pulse | ||||||
V1 | 24V power, on-site display, 4-20mA, RS485, Impulse output | |||||||
V1 B |
24V +battery power supply, on-site display, 4-20 mA, RS485, pulse output | |||||||
Pressure Class | N | Normal | ||||||
H | High pressure |
PACKING & SHIPPING
We will deliver your ordered product at the earliest date as required by you, ensuring reliable and prompt service tailored to meet your specific timeline.Installation Requirements
Piping Condition
The installation of the Wear Resistant Vortex Flowmeter requires specific straight pipe sections before and after the installation point. The common requirements are as follows (D represents the pipe diameter):
Piping condition | upstream | Downstream |
Concentric shrinkage pipe full open gate valve |
15D | 5D |
∠90° square elbow | 20D | 5D |
Same plane 2∠90°elbow | 25D | 5D |
Semi-open gate valve regulating valve | 50D | 5D |
Different plane 2∠90°elbow | 40D | 5D |
With rectifier tube bundle | 12D | 5D |
1.
The sensor should be mounted on a pipe that is horizontal, vertical, or inclined (with liquid flowing from bottom to top) and matches the sensor diameter. Ensure there is a straight pipe length upstream and downstream of the sensor, meeting the requirements of 15-20D for the front section and 5-10D for the rear section.
2.
The pipe around the liquid sensor must be filled with the liquid being measured.
3.
Avoid installing the sensor on pipes subject to strong mechanical vibrations.
4.
The inner diameter of the straight pipe should align as closely as possible with the sensor diameter. For slight mismatches, a larger pipe with an error ≤3% and not surpassing 5mm is acceptable. Avoid installation in areas with strong electromagnetic interference, restricted space, or inconvenient maintenance..
5.
Horizontal pipeline installation is the most common for flow sensors. For gas flows containing minor liquid amounts, position the sensor at a higher pipeline point. For liquid flows with minor gas presence, mount the sensor at a lower pipeline point.
6.
Vertical pipeline sensor installation: For gas flows, mount the sensor on a vertical pipe regardless of flow direction. With gas containing minor liquid, the flow should move from bottom to top. For liquid flows, ensure the liquid flows from bottom to top to prevent additional probe weight.
7.
Side installation on horizontal pipelines is possible for any fluid, especially superheated steam, saturated steam, and low-temperature liquids. Side mounting is preferred if feasible, as it reduces temperature impact on the amplifier.
8.
Inverted sensor installation on horizontal pipelines is generally discouraged. It is unsuitable for general gases or superheated steam but can measure saturated steam and high-temperature liquids or in conditions requiring frequent pipeline cleaning.
9.
When measuring high-temperature steam in insulated pipelines, the insulation thickness should not exceed one-third of the bracket height.
10.
Pressure and temperature measurement points selection: If measurements are required near the sensor, the pressure measurement point should be 3-5D downstream, and the temperature measurement point should be 6-8D downstream.