Product Overview
The ZZYS30 Vortex Flowmeter: a cutting-edge velocity flow instrument designed to meet the diverse needs of various industries.
Perfect for measuring, monitoring, and controlling the flow of liquids, steam, and most gases, ensuring optimal performance and reliability.
Engineered with a revolutionary structure that withstands mechanical vibrations, impacts, and contamination effortlessly.
Featuring no moving parts, zero wear and tear, minimal pressure loss, and requiring no mechanical maintenance, this flowmeter promises stable performance and exceptional accuracy.
Installation is a breeze, and the sensor and signal converter are easily configurable to suit your specific needs.
Product Features
Exceptionally versatile, ideal for measuring steam, gas, and liquid flows with incredible precision.
Superior vibration resistance and zero drift at zero point, effectively nullifying the impact of external vibrations.
The ZZYS30 also offers integrated temperature and pressure options, significantly reducing installation costs.
Supports multiple output options, including (0-5) kHz frequency, (4-20) mA, HART communication, and Modbus protocol communication.
Seamlessly set parameters via Bluetooth communication. Boasts wear- and dirt-resistance, requires no mechanical maintenance, and features an explosion-proof design for enhanced safety and longevity.
Technical Index
Measurement Medium: Gas, Liquid, Steam
Connection Methods: Flange Clamp Type, Flange Type, Insertion Type
Caliber Specifications:
Flange Clamping Type: 25, 32, 50, 80, 100.
Flange Connection Type Caliber Selection: 100, 150, 200
Flow Measurement Range: Normal Measurement Flow Velocity Range: Reynolds Number 1.5×104~4×106; Gas: 5~50m/s; Liquid: 0.5~7m/s.
Normal Measurement Flow Range: Liquid,
Gas Flow Measurement Range: See Table 2.
Steam Flow Range: See Table 3.
Measurement Accuracy: 1.0 Class, 1.5 Class
Measured Medium Temperature:
Room Temperature: -25ºC~100ºC; High Temperature: -25ºC~150ºC, -25ºC~250ºC. Output Signal: Pulse Voltage Output Signal, High Level: 8~10V, Low Level: 0.7~1.3V, Pulse Duty Cycle: About 50%, Transmission Distance: 100m
Pulse Current Remote Transmission Signal: 4-20 mA, Transmission Distance: 1000m. Instrument Use Environment: Temperature: -25ºC~+55ºC, Humidity: 5~90% RH@50ºC. Material: Stainless Steel, Aluminum Alloy
Power Supply: DC24V or Lithium Battery 3.6V
Explosion-Proof Grade: Intrinsically Safe iaIIbT3-T6, Protection Level: IP65.
Technical parameters | |
Medium | Steam, Gas, Liquid |
Measuring range | See flow1-3 |
Caliber | DN15, DN25, DN40, DN50, DN80, DN100, DN200, DN250, DN300 |
Medium pressure | ≤100 bar, more pressure need be customized |
Medium temperature | -40°C~+240°C |
Ambient temperature | Ordinary type: -40°C~+85°C Ex-proof type: -40°C~+60°C |
Accuracy | Liquid, Re≥20000 is ±1.0%, gas and steam, ±1.5% |
Repeatability | ±0.3% |
Material | Measuring pipe:304,316L, HC276 |
Sensor: 316L, HC276 | |
Converter shell: casting aluminum | |
Instrument caliber | Flange connection: DN15-DN300 |
Clamping connection: DN15-DN100 | |
Flange standard | DIN, ANSI, HG20592 (Can be customized) |
Pressure loss Gasandliquid saturated steam |
ΔP=Cqv²Px ΔP: pressure loss(pa) qv: volume flow qm: mass flow ΔP=Cqm²Px PX: density C: constent |
Display | Two-line LCD display, four button operation Instantaneous flow, accumulated flow, vortex frequency, medium temperature, pressure(selectable), circular or non-circular display |
Power supply | Ordinary type: (14~36) VDC Ex-proof type: (14~30) VDC Battery power supply |
Loading | No-ex-proof: RB=(UB-14DVC)/22MA≤1200Ω Ex-proof: RB=(UB-14DVC)/22MA≤600Ω |
Output | Two wire 4~20mA |
Ex-proof class | Exd II CT6 CE19.1438 Ex ( ia ) II CT6 |
Cable interface | 1/2''NPT( Internal thread, recommended), M201.5 (Internal thread) |
Housing protection class | IP67 |
Connection type | Flange (DN15-DN300), Clamping (DN15-DN100) |
Mounting type | Integral mounting, split mounting (special shielded cable connect the pipe and indicator) |
Gas | |||
Air: t=20°C p=1.013bar abs =1.7210-4 mpa.s Q: flow (sheet 1) | |||
Nominal diameter | Internal diameter | Qmin(m3/h) | Qmax(m3/h) |
DN15 | 16 | 6.79 | 32.56 |
DN25 | 24 | 10.20 | 113.94 |
DN40 | 38 | 25.3 | 326.63 |
DN50 | 50 | 43.89 | 565.49 |
DN80 | 74 | 96.14 | 1238.64 |
DN100 | 97 | 165.14 | 2128.27 |
DN150 | 146 | 374.23 | 4821.57 |
DN200 | 193 | 702.95 | 9056.8 |
DN250 | 253 | 1123.7 | 14478 |
DN300 | 305 | 1632.1 | 21028 |
Liquid | |||
Water: t=20°C p=1.013bar abs ≤10cp Q: flow | |||
Nominal diameter | Internal diameter | Qmin(m3/h) | Qmax(m3/h) |
DN15 | 16 | 0.45 | 5 |
DN25 | 24 | 0.81 | 11.40 |
DN40 | 38 | 2.04 | 28.57 |
DN50 | 50 | 3.53 | 49.47 |
DN80 | 74 | 7.74 | 108.37 |
DN100 | 97 | 13.30 | 186.21 |
DN150 | 146 | 30.13 | 421.86 |
DN200 | 193 | 52.66 | 792.42 |
DN250 | 253 | 90.5 | 1266.8 |
DN300 | 305 | 113.41 | 1839.8 |
Saturated steam | |||||||||
Nominal Diameter |
Inner Diameter |
Mass flow Qm (kg/h) under different pressure and density | |||||||
P=1bar G | P=3.5bar G | P=5.2bar G | P=7 bar G | ||||||
ρ=1.13kg/m3 | ρ=2.43kg/m3 | ρ=3.28kg/m3 | ρ=4.17kg/m3 | ||||||
t=120.6°C | t=148.2°C | t=160.4°C | t=170.6°C | ||||||
min | max | min | max | min | max | min | max | ||
DN15 | 16 | 5.87 | 36.97 | 7.68 | 79 | 8.93 | 106.68 | 10.06 | 135.69 |
DN25 | 24 | 11.82 | 129.39 | 17.26 | 276.4 | 20.09 | 373.53 | 22.66 | 474.82 |
DN40 | 38 | 29.64 | 370.71 | 43.33 | 792.33 | 50.63 | 1070.2 | 56.8 | 1361.2 |
DN50 | 50 | 51.31 | 641.82 | 75.02 | 1371.8 | 87.19 | 1852.8 | 98.33 | 2356.6 |
DN80 | 74 | 112.41 | 1405.8 | 164.33 | 3004.7 | 191 | 4058.4 | 215.39 | 5161.8 |
DN100 | 97 | 193.14 | 2415.5 | 282.36 | 5162.7 | 328.16 | 6973.3 | 370.09 | 8869.2 |
DN150 | 146 | 437.56 | 5472.4 | 639.69 | 11696 | 743.45 | 15798 | 838.44 | 20093 |
DN200 | 193 | 821.91 | 10279 | 1201.6 | 21970 | 1396.5 | 29675 | 1574.9 | 37743 |
DN250 | 253 | 1313.9 | 16433 | 1920.9 | 35122 | 2232.5 | 47439 | 2517.7 | 60337 |
DN300 | 305 | 1908.3 | 23866 | 2789.8 | 51010 | 3242.4 | 68899 | 3656.6 | 87630 |
Nominal Diameter |
Inner Diameter |
Mass flow Qm (kg/h) under different pressure and density | |||||||
P=10.5 bar G | P=14 bar G | P=17.5 bar G | P=20 bar G | ||||||
ρ=5.89kg/m3 | ρ=7.6kg/m3 | ρ=9.32kg/m3 | ρ=10.54kg/m3 | ||||||
t=186.2°C | t=198.5°C | t=208.5°C | t=215.6°C | ||||||
min | max | min | max | min | max | min | max | ||
DN15 | 16 | 12.78 | 191.71 | 16.51 | 247.55 | 20.23 | 303.36 | 22.89 | 343.32 |
DN25 | 24 | 26.93 | 670.88 | 30.6 | 857.88 | 33.87 | 955.48 | 36.04 | 1201.41 |
DN40 | 38 | 67.51 | 1878.2 | 76.72 | 2150.7 | 84.93 | 2395.3 | 90.35 | 2557.7 |
DN50 | 50 | 116.89 | 3251.7 | 132.82 | 3723.4 | 147.03 | 4147 | 156.42 | 4428.1 |
DN80 | 74 | 256.03 | 7122.4 | 290.93 | 8155.8 | 322.06 | 9083.7 | 342.62 | 9699.3 |
DN100 | 97 | 439.91 | 12238 | 499.9 | 14013 | 553.38 | 15608 | 588.69 | 16666 |
DN150 | 146 | 996.62 | 27725 | 1132.5 | 31747 | 1253.7 | 35359 | 1333.7 | 37756 |
DN200 | 193 | 1872.1 | 52079 | 2127.3 | 59634 | 2354.9 | 66419 | 2505.2 | 70921 |
DN250 | 253 | 2992.7 | 83254 | 3400.71 | 95333 | 3764.6 | 106180 | 4004.9 | 113380 |
DN300 | 305 | 4346.5 | 120920 | 4939.1 | 138460 | 5467.5 | 154210 | 5816.5 | 164660 |
Selection list | ||||||||
model | Explanation | |||||||
ZZY30 | ||||||||
Connection | F | Flange connection | ||||||
W | Flange clamping | |||||||
Temperature Resistance Class |
T1 | Match with 250°c probe | ||||||
T2 | Match with 350°c probe | |||||||
Nominal diameter |
015 | DN15 | ||||||
020 | DN20 | |||||||
025 | DN25 | |||||||
032 | DN32 | |||||||
040 | DN40 | |||||||
050 | DN50 | |||||||
065 | DN65 | |||||||
080 | DN80 | |||||||
100 | DN100 | |||||||
125 | DN125 | |||||||
150 | DN150 | |||||||
200 | DN200 | |||||||
250 | DN250 | |||||||
300 | DN300 | |||||||
Structure |
Z | Integrated T and P compensation | ||||||
F | Regular model | |||||||
S | Split | |||||||
Material | R1 | 304 | ||||||
RL | 316L | |||||||
Instrument model |
N | 24V power supply Output 3 wire pulse | ||||||
V1 | 24V power, on-site display, 4-20mA, RS485, Impulse output | |||||||
V1 B |
24V +battery power supply, on-site display, 4-20 mA, RS485, pulse output | |||||||
Pressure Class | N | Normal | ||||||
H | High pressure |
PACKING & SHIPPING
We are committed to delivering your ordered products at the earliest possible date, precisely as per your specifications.Installation Requirements
Piping Condition
The installation of a vortex flowmeter requires specific straight pipe sections both upstream and downstream. The common configurations are as follows (D represents the diameter of the pipe):
Piping condition | upstream | Downstream |
Concentric shrinkage pipe full open gate valve |
15D | 5D |
∠90° square elbow | 20D | 5D |
Same plane 2∠90°elbow | 25D | 5D |
Semi-open gate valve regulating valve | 50D | 5D |
Different plane 2∠90°elbow | 40D | 5D |
With rectifier tube bundle | 12D | 5D |
1.
Install the sensor on a horizontal, vertical, or inclined pipe (with liquid flowing from bottom to top) that matches the sensor's diameter. Ensure adequate straight pipe lengths: 15-20D upstream and 5-10D downstream.
2.
Ensure the pipe near the liquid sensor is fully filled with the liquid to be measured.
3.
Avoid installing the sensor on pipes subject to strong mechanical vibrations.
4.
The inner diameter of the straight pipe should closely match the sensor diameter. If not, use a slightly larger pipe, ensuring an error of ≤3% and not exceeding 5mm. Do not install the sensor in areas with strong electromagnetic interference, restricted space, or where maintenance is difficult. Installation requirements.
5.
Horizontal pipeline installation is most common. For gas flow with small liquid content, install the sensor at a higher pipeline point. For liquid flow with small gas content, install at a lower point.
6.
Vertical pipeline installation involves no flow direction restriction for gas flow. For gas with small liquid content, ensure flow direction is from bottom to top. For liquid flow, flow should be from bottom to top to prevent additional weight on the probe.
7.
Side installation on horizontal pipelines is possible for any fluid, especially superheated steam, saturated steam, and low-temperature liquids. Side mounting minimizes temperature impact on the amplifier.
8.
Inverted installation on horizontal pipelines is generally not recommended. It is unsuitable for general gases or superheated steam but can be used for saturated steam and high-temperature liquids, or where frequent pipeline cleaning is required.
9.
For pipelines with insulation layers measuring high-temperature steam, the insulation should not exceed one-third the height of the bracket.
10.
When measuring pressure and temperature near the sensor, place pressure measurement points 3-5D downstream and temperature measurement points 6-8D downstream.