Customization: | Available |
---|---|
After-sales Service: | 24/7 After Sales Services |
Warranty: | 12 Months From Delivery |
Still deciding? Get samples of US$ 400/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Overview
The ZZYS30 vortex flowmeter is a state-of-the-art velocity flow instrument designed for a diverse range of applications.
This versatile device is ideal for measuring, monitoring, and controlling the flow of liquids, steam, and various gases with unparalleled precision.
Engineered with an innovative structure, it boasts high resistance to mechanical vibrations, impacts, and contamination, ensuring robust performance.
Featuring no moving parts, it eliminates wear and tear, requires no mechanical maintenance, offers low pressure loss, and guarantees stable performance with exceptional accuracy.
Installation is a breeze, and the sensor and signal converter can be easily matched to meet specific needs.
Product features:
Broad application range, perfectly suited for measuring the flow of steam, gas, and liquid in various environments.
Exceptional vibration resistance with zero-point stability, effectively mitigating the impact of external vibrations.
The ZZY30 offers integrated temperature and pressure measurement options, significantly reducing installation costs for users.
Provides versatile output options including (0-5) kHz frequency, (4-20) mA output, and HART communication or Modbus protocol communication.
Supports Bluetooth communication for easy parameter setting, is wear- and dirt-resistant, requires no mechanical maintenance, boasts a long service life, and is explosion-proof for enhanced safety.
Technical Index
Measurement Medium: Suitable for gas, liquid, and steam applications.
Connection Method: Available in flange clamp type, flange type, and insertion type configurations.
Caliber Specifications:
Flange Clamping Type: Compatible with diameters of 25, 32, 50, 80, and 100.
Flange Connection Type: Offers caliber selections of 100, 150, and 200.
Flow Measurement Range: Ensures accurate readings within a normal flow velocity range. Reynolds number: 1.5×104~4×106; Gas: 5~50 m/s; Liquid: 0.5~7 m/s.
Normal Measurement Flow Range: Applicable for liquid flow measurements,
Gas Flow Measurement Range: Refer to Table 2 for precise details.
Steam Flow Range: Refer to Table 3 for precise details.
Measurement Accuracy: Available in Class 1.0 and Class 1.5 for dependable precision.
Measured Medium Temperature:
Room Temperature: -25ºC to 100ºC; High Temperature Options: -25ºC to 150ºC or -25ºC to 250ºC. Output Signal: Pulse voltage output signal with a high level of 8~10V, low level of 0.7~1.3V. Pulse duty cycle approximately 50%, transmission distance up to 100 meters.
Pulse Current Remote Transmission Signal: 4-20 mA, with a transmission distance of up to 1000 meters. Instrument Use Environment: Temperature range -25ºC to +55ºC, humidity range 5~90% RH at 50ºC. Material: Constructed from durable stainless steel and aluminum alloy.
Power Supply: Operates on DC24V or a 3.6V lithium battery.
Explosion-Proof Grade: Intrinsically safe iaIIbT3-T6, protection level IP65.
Technical parameters | |
Medium | Steam, Gas, Liquid |
Measuring range | See flow1-3 |
Caliber | DN15, DN25, DN40, DN50, DN80, DN100, DN200, DN250, DN300 |
Medium pressure | ≤100 bar, more pressure need be customized |
Medium temperature | -40°C~+240°C |
Ambient temperature | Ordinary type: -40°C~+85°C Ex-proof type: -40°C~+60°C |
Accuracy | Liquid, Re≥20000 is ±1.0%, gas and steam, ±1.5% |
Repeatability | ±0.3% |
Material | Measuring pipe:304,316L, HC276 |
Sensor: 316L, HC276 | |
Converter shell: casting aluminum | |
Instrument caliber | Flange connection: DN15-DN300 |
Clamping connection: DN15-DN100 | |
Flange standard | DIN, ANSI, HG20592 (Can be customized) |
Pressure loss Gasandliquid saturated steam |
ΔP=Cqv²Px ΔP: pressure loss(pa) qv: volume flow qm: mass flow ΔP=Cqm²Px PX: density C: constent |
Display | Two-line LCD display, four button operation Instantaneous flow, accumulated flow, vortex frequency, medium temperature, pressure(selectable), circular or non-circular display |
Power supply | Ordinary type: (14~36) VDC Ex-proof type: (14~30) VDC Battery power supply |
Loading | No-ex-proof: RB=(UB-14DVC)/22MA≤1200Ω Ex-proof: RB=(UB-14DVC)/22MA≤600Ω |
Output | Two wire 4~20mA |
Ex-proof class | Exd II CT6 CE19.1438 Ex ( ia ) II CT6 |
Cable interface | 1/2''NPT( Internal thread, recommended), M201.5 (Internal thread) |
Housing protection class | IP67 |
Connection type | Flange (DN15-DN300), Clamping (DN15-DN100) |
Mounting type | Integral mounting, split mounting (special shielded cable connect the pipe and indicator) |
Gas | |||
Air: t=20°C p=1.013bar abs =1.7210-4 mpa.s Q: flow (sheet 1) | |||
Nominal diameter | Internal diameter | Qmin(m3/h) | Qmax(m3/h) |
DN15 | 16 | 6.79 | 32.56 |
DN25 | 24 | 10.20 | 113.94 |
DN40 | 38 | 25.3 | 326.63 |
DN50 | 50 | 43.89 | 565.49 |
DN80 | 74 | 96.14 | 1238.64 |
DN100 | 97 | 165.14 | 2128.27 |
DN150 | 146 | 374.23 | 4821.57 |
DN200 | 193 | 702.95 | 9056.8 |
DN250 | 253 | 1123.7 | 14478 |
DN300 | 305 | 1632.1 | 21028 |
Liquid | |||
Water: t=20°C p=1.013bar abs ≤10cp Q: flow | |||
Nominal diameter | Internal diameter | Qmin(m3/h) | Qmax(m3/h) |
DN15 | 16 | 0.45 | 5 |
DN25 | 24 | 0.81 | 11.40 |
DN40 | 38 | 2.04 | 28.57 |
DN50 | 50 | 3.53 | 49.47 |
DN80 | 74 | 7.74 | 108.37 |
DN100 | 97 | 13.30 | 186.21 |
DN150 | 146 | 30.13 | 421.86 |
DN200 | 193 | 52.66 | 792.42 |
DN250 | 253 | 90.5 | 1266.8 |
DN300 | 305 | 113.41 | 1839.8 |
Saturated steam | |||||||||
Nominal Diameter |
Inner Diameter |
Mass flow Qm (kg/h) under different pressure and density | |||||||
P=1bar G | P=3.5bar G | P=5.2bar G | P=7 bar G | ||||||
ρ=1.13kg/m3 | ρ=2.43kg/m3 | ρ=3.28kg/m3 | ρ=4.17kg/m3 | ||||||
t=120.6°C | t=148.2°C | t=160.4°C | t=170.6°C | ||||||
min | max | min | max | min | max | min | max | ||
DN15 | 16 | 5.87 | 36.97 | 7.68 | 79 | 8.93 | 106.68 | 10.06 | 135.69 |
DN25 | 24 | 11.82 | 129.39 | 17.26 | 276.4 | 20.09 | 373.53 | 22.66 | 474.82 |
DN40 | 38 | 29.64 | 370.71 | 43.33 | 792.33 | 50.63 | 1070.2 | 56.8 | 1361.2 |
DN50 | 50 | 51.31 | 641.82 | 75.02 | 1371.8 | 87.19 | 1852.8 | 98.33 | 2356.6 |
DN80 | 74 | 112.41 | 1405.8 | 164.33 | 3004.7 | 191 | 4058.4 | 215.39 | 5161.8 |
DN100 | 97 | 193.14 | 2415.5 | 282.36 | 5162.7 | 328.16 | 6973.3 | 370.09 | 8869.2 |
DN150 | 146 | 437.56 | 5472.4 | 639.69 | 11696 | 743.45 | 15798 | 838.44 | 20093 |
DN200 | 193 | 821.91 | 10279 | 1201.6 | 21970 | 1396.5 | 29675 | 1574.9 | 37743 |
DN250 | 253 | 1313.9 | 16433 | 1920.9 | 35122 | 2232.5 | 47439 | 2517.7 | 60337 |
DN300 | 305 | 1908.3 | 23866 | 2789.8 | 51010 | 3242.4 | 68899 | 3656.6 | 87630 |
Nominal Diameter |
Inner Diameter |
Mass flow Qm (kg/h) under different pressure and density | |||||||
P=10.5 bar G | P=14 bar G | P=17.5 bar G | P=20 bar G | ||||||
ρ=5.89kg/m3 | ρ=7.6kg/m3 | ρ=9.32kg/m3 | ρ=10.54kg/m3 | ||||||
t=186.2°C | t=198.5°C | t=208.5°C | t=215.6°C | ||||||
min | max | min | max | min | max | min | max | ||
DN15 | 16 | 12.78 | 191.71 | 16.51 | 247.55 | 20.23 | 303.36 | 22.89 | 343.32 |
DN25 | 24 | 26.93 | 670.88 | 30.6 | 857.88 | 33.87 | 955.48 | 36.04 | 1201.41 |
DN40 | 38 | 67.51 | 1878.2 | 76.72 | 2150.7 | 84.93 | 2395.3 | 90.35 | 2557.7 |
DN50 | 50 | 116.89 | 3251.7 | 132.82 | 3723.4 | 147.03 | 4147 | 156.42 | 4428.1 |
DN80 | 74 | 256.03 | 7122.4 | 290.93 | 8155.8 | 322.06 | 9083.7 | 342.62 | 9699.3 |
DN100 | 97 | 439.91 | 12238 | 499.9 | 14013 | 553.38 | 15608 | 588.69 | 16666 |
DN150 | 146 | 996.62 | 27725 | 1132.5 | 31747 | 1253.7 | 35359 | 1333.7 | 37756 |
DN200 | 193 | 1872.1 | 52079 | 2127.3 | 59634 | 2354.9 | 66419 | 2505.2 | 70921 |
DN250 | 253 | 2992.7 | 83254 | 3400.71 | 95333 | 3764.6 | 106180 | 4004.9 | 113380 |
DN300 | 305 | 4346.5 | 120920 | 4939.1 | 138460 | 5467.5 | 154210 | 5816.5 | 164660 |
Selection list | ||||||||
model | Explanation | |||||||
ZZY30 | ||||||||
Connection | F | Flange connection | ||||||
W | Flange clamping | |||||||
Temperature Resistance Class |
T1 | Match with 250°c probe | ||||||
T2 | Match with 350°c probe | |||||||
Nominal diameter |
015 | DN15 | ||||||
020 | DN20 | |||||||
025 | DN25 | |||||||
032 | DN32 | |||||||
040 | DN40 | |||||||
050 | DN50 | |||||||
065 | DN65 | |||||||
080 | DN80 | |||||||
100 | DN100 | |||||||
125 | DN125 | |||||||
150 | DN150 | |||||||
200 | DN200 | |||||||
250 | DN250 | |||||||
300 | DN300 | |||||||
Structure |
Z | Integrated T and P compensation | ||||||
F | Regular model | |||||||
S | Split | |||||||
Material | R1 | 304 | ||||||
RL | 316L | |||||||
Instrument model |
N | 24V power supply Output 3 wire pulse | ||||||
V1 | 24V power, on-site display, 4-20mA, RS485, Impulse output | |||||||
V1 B |
24V +battery power supply, on-site display, 4-20 mA, RS485, pulse output | |||||||
Pressure Class | N | Normal | ||||||
H | High pressure |
PACKING & SHIPPING
We will deliver your order at the earliest date required by you, ensuring timely and efficient service.Installation Requirements
Piping Condition
The installation of the High Accuracy Vortex Flowmeter for Liquid and Gas Applications requires specific straight pipe sections before and after the sensor. The common scenarios are as follows (D is the diameter of the pipe):
Piping condition | upstream | Downstream |
Concentric shrinkage pipe full open gate valve |
15D | 5D |
∠90° square elbow | 20D | 5D |
Same plane 2∠90°elbow | 25D | 5D |
Semi-open gate valve regulating valve | 50D | 5D |
Different plane 2∠90°elbow | 40D | 5D |
With rectifier tube bundle | 12D | 5D |
1.
The sensor should be mounted on a horizontal, vertical, or inclined pipe (with liquid flowing from bottom to top) that matches the sensor's diameter. Ensure sufficient lengths of straight pipe upstream (15-20D) and downstream (5-10D) of the sensor.
2.
The pipe near the liquid sensor should be completely filled with the liquid being measured.
3.
Avoid installing the sensor on pipes experiencing strong mechanical vibrations.
4.
The inner diameter of the straight pipe should align as closely as possible with the sensor's diameter. If a match is not feasible, use a slightly larger pipe with a diameter error of ≤3% and not exceeding 5mm. Do not place the sensor in areas with strong electromagnetic interference, constrained space, or where maintenance is inconvenient..
5.
Horizontal pipeline installation is most common. For gas flow measurement containing a small amount of liquid, install the sensor at a higher point in the pipeline. For liquid flow containing a small amount of gas, place the sensor at a lower point.
6.
Vertical pipeline sensor installation: For gas flow measurement, the sensor can be installed without restricting flow direction. If the gas contains liquid, ensure the gas flows from bottom to top. For liquid flow, the liquid should also flow from bottom to top to prevent extra weight on the probe.
7.
Side installation on horizontal pipelines: Sensors can be side-mounted regardless of fluid type, especially for superheated steam, saturated steam, and low-temperature liquids. If feasible, side mounting is preferred to reduce temperature effects on the amplifier.
8.
Inverted installation on horizontal pipelines is generally not recommended and is unsuitable for general gases or superheated steam. It can be used for saturated steam and high-temperature liquids, or in situations requiring frequent pipeline cleaning.
9.
For pipelines with insulation layers, ensure the insulation does not exceed one-third of the bracket height when measuring high-temperature steam.
10.
Selecting pressure and temperature measurement points: For measurements near the sensor, position the pressure measurement point 3-5D downstream and the temperature measurement point 6-8D downstream of the sensor.