Customization: | Available |
---|---|
After-sales Service: | 24/7 Online After Sales Services |
Warranty: | 12 Months After Delivery Date |
Still deciding? Get samples of US$ 450/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
At Shandong Zhongziyi Intelligent Technology Co., Ltd., we are dedicated to ensuring that your High Precision Electromagnetic Flowmeter with ANSI Standards and Output reaches you promptly. We pride ourselves on providing timely and efficient service, meticulously tailored to meet your specific delivery requirements.The installation of the High Precision Electromagnetic Flowmeter with ANSI Standards and Output from Shandong Zhongziyi Intelligent Technology Co., Ltd. varies depending on the pipeline conditions at the site. For pipelines without a ball valve, it should be installed on a non-pressurized line, allowing for the selection of flowmeters that do not include a ball valve.
A hole with a diameter of 50mm should be made in the pipeline, and preparations should be made to weld a connecting pipe to the opening in the pipeline.
In situations requiring continuous flow during loading and unloading or where media overflow must be prevented, a ball valve is essential. This necessitates selecting an insertion-type electromagnetic flowmeter with a ball valve structure.
A hole with a diameter of 50mm should be made in the pipeline, and preparations should be made to weld a connecting pipe to the opening in the pipeline.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
The required straight pipe sections are 5D upstream and 3D downstream. This ensures proper function and precision of the electromagnetic flowmeter.
The measurement principle of the electromagnetic flowmeter is independent of the flow characteristics.
If turbulence and vortices are generated in the non-measurement area of the pipeline (e.g., elbows, tangential throttling, or a partially open shut-off valve upstream), it will not affect the measurement.
However, steady-state vortices in the measurement area will impact the measurement's stability and accuracy.
In such cases, measures should be taken to stabilize the flow distribution:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To mitigate the effects of vortices and flow field distortion, specific lengths for the straight pipe sections upstream and downstream of the flowmeter are required; otherwise, measurement accuracy could be compromised. Installing a straightener is also advisable, and the meter should not be placed near control valves or partially open valves.
2.2. Requirements for Process Pipes The flowmeter has specific requirements for the upstream and downstream process pipes at the installation point. To ensure measurement accuracy, the inner diameter of the upstream and downstream pipes should match the sensor's diameter, meeting the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter, and D is the pipe's inner diameter). The process pipe and the sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance of the flowmeter, installing a bypass pipe is highly recommended. This is especially essential for handling heavily contaminated fluids and scenarios where the flowmeter needs cleaning without halting fluid flow. a. Facilitates easy maintenance of the flowmeter. b. Mandatory for heavily contaminated fluids. c. Enables cleaning of the flowmeter without stopping the fluid flow.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections Inlet/Outlet Straight Pipe Sections: For optimal performance, the inlet should be ≥ 10×DN, and the outlet should be ≥ 5×DN.
3.2. Requirements for Grounding Points To guarantee the reliable operation and enhanced measurement accuracy of the instrument, it should remain unaffected by external parasitic potentials. The sensor must be well-grounded, maintaining a grounding resistance of less than 10. (If the metal pipeline is already well-grounded, an additional dedicated grounding device is unnecessary.)
3.3. Requirements for Installation Position Refer to the diagram for precise installation positioning.
COMPANY AND FACTORY PICTURE: