Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
We are committed to delivering your ordered product at the earliest date as per your requirements, ensuring timely and efficient service. Our dedication to reliability and speed means you can expect seamless delivery, right when you need it.The installation of the electromagnetic flowmeter is contingent upon the specific site pipeline conditions. For pipelines without a ball valve, the flowmeter should be installed in a non-pressurized pipe. This flexibility allows for the selection of flowmeters without a ball valve under non-pressurized conditions.
Create a 50mm diameter hole in the pipeline and prepare to weld a connecting pipe to this opening.
In scenarios requiring uninterrupted flow during loading and unloading, or where media overflow is unacceptable, a ball valve is essential. Therefore, selecting an insertion-type electromagnetic flowmeter with a ball valve structure is necessary.
Create a 50mm diameter hole in the pipeline and prepare to weld a connecting pipe to this opening.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
To ensure optimal performance of the electromagnetic flowmeter and meet accuracy requirements, it is necessary to have straight pipe sections measuring 5D upstream and 3D downstream.
The measurement principle of the electromagnetic flowmeter is independent of flow characteristics.
Even with the presence of turbulence and vortices in the non-measurement area of the pipeline-such as at elbows, tangential throttling, or a partially open shut-off valve upstream-the measurement remains unaffected.
However, steady-state vortices within the measurement area can compromise the stability and accuracy of the readings.
In such cases, measures should be implemented to stabilize flow distribution:
1.2. Pipeline-type electromagnetic flowmeter
2.1. Requirements for straight sections To minimize the impact of vortices and flow field distortion, specific lengths for the straight pipe sections upstream and downstream of the flowmeter must be adhered to. Failure to do so will affect measurement accuracy (a straightener is also an option, and it is advisable to avoid installation near control valves and partially open valves).
2.2. Requirements for the process pipes The flowmeter has precise requirements for the upstream and downstream process pipes at the installation point. Non-compliance can affect measurement accuracy. a. The inner diameter of the upstream and downstream process pipes should match the sensor's, adhering to the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter, and D is the process pipe's inner diameter). b. The process pipe and the sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance of the flowmeter, it is highly recommended to install a bypass pipe. This becomes imperative in handling heavily contaminated fluids or scenarios where the flowmeter requires cleaning without halting the fluid flow: a. Facilitates convenient maintenance of the flowmeter. b. Essential for managing heavily contaminated fluids. c. Ensures continuous fluid flow during necessary cleaning of the flowmeter.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections Inlet/Outlet Straight Pipe Sections: The inlet should be at least 10 times the nominal diameter (≥ 10×DN), and the outlet should be at least 5 times the nominal diameter (≥ 5×DN).
3.2. Requirements for Grounding Points To guarantee the reliable operation of the instrument and enhance measurement precision, it should remain unaffected by external parasitic potentials. The sensor must be properly grounded, with a grounding resistance of less than 10 ohms. (A dedicated grounding device is unnecessary if the metal pipeline is sufficiently grounded.)
3.3. Requirements for Installation Position Refer to the diagram for the specific installation position requirements.