Customization: | Available |
---|---|
After-sales Service: | 24/7 After Sales Services |
Warranty: | 12 Months From Delivery |
Still deciding? Get samples of US$ 400/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Overview
The ZZYS30 vortex flowmeter is a versatile velocity flow instrument designed for a multitude of applications.
It is ideal for measuring, monitoring, and controlling the flow of liquids, steam, and a broad spectrum of gases.
Engineered with an innovative structure, it is resilient against mechanical vibrations, impacts, and contamination.
Boasting no moving parts, this flowmeter ensures no wear and tear, eliminating the need for mechanical maintenance. It offers low pressure loss, stable performance, and exceptional accuracy.
Installation is a breeze, with sensor and signal converter configurations customizable to your needs.
Product features:
Extensive application range, adept at measuring the flow of steam, gas, and liquid.
Outstanding vibration performance with zero drift at zero point, effectively negating the influence of external vibrations.
ZZY30 provides integrated temperature and pressure options, reducing installation costs for users.
Offers (0-5) kHz frequency output, (4-20) mA output, and supports HART communication or Modbus protocol communication.
Features Bluetooth communication for convenient parameter setting. It is wear-resistant, dirt-resistant, requires no mechanical maintenance, has a long service life, and is explosion-proof for enhanced safety.
Technical Index
Measurement Medium: Gas, Liquid, Steam
Connection Method: Available in Flange Clamp Type, Flange Type, and Insertion Type
Caliber Specifications:
Flange Clamping Type: 25mm, 32mm, 50mm, 80mm, 100mm
Flange Connection Type: Caliber Selections include 100mm, 150mm, 200mm
Flow Measurement Range: Normal Measurement Flow Velocity Range with Reynolds Number 1.5×10~4×10; Gas: 5~50m/s; Liquid: 0.5~7m/s
Normal Measurement Flow Range: Liquid
Gas Flow Measurement Range: Refer to Table 2
Steam Flow Range: Refer to Table 3
Measurement Accuracy: 1.0 Class, 1.5 Class
Measured Medium Temperature:
Temperature Ranges from Room Temperature (-25ºC~100ºC), High Temperature (-25ºC~150ºC, -25ºC~250ºC). Output Signal: Pulse Voltage Output Signal with High Level 8~10V, Low Level 0.7~1.3V. Pulse Duty Cycle is approximately 50%, with a Transmission Distance of 100m.
Pulse Current Remote Transmission Signal: 4-20 mA, Transmission Distance is 1000m. Instrument Use Environment: Temperature Range -25ºC~+55ºC, Humidity: 5~90% RH at 50ºC. Material: Stainless Steel, Aluminum Alloy
Power Supply: DC24V or Lithium Battery 3.6V
Explosion-Proof Grade: Intrinsically Safe iaIIbT3-T6, Protection Level IP65
Technical parameters | |
Medium | Steam, Gas, Liquid |
Measuring range | See flow1-3 |
Caliber | DN15, DN25, DN40, DN50, DN80, DN100, DN200, DN250, DN300 |
Medium pressure | ≤100 bar, more pressure need be customized |
Medium temperature | -40°C~+240°C |
Ambient temperature | Ordinary type: -40°C~+85°C Ex-proof type: -40°C~+60°C |
Accuracy | Liquid, Re≥20000 is ±1.0%, gas and steam, ±1.5% |
Repeatability | ±0.3% |
Material | Measuring pipe:304,316L, HC276 |
Sensor: 316L, HC276 | |
Converter shell: casting aluminum | |
Instrument caliber | Flange connection: DN15-DN300 |
Clamping connection: DN15-DN100 | |
Flange standard | DIN, ANSI, HG20592 (Can be customized) |
Pressure loss Gasandliquid saturated steam |
ΔP=Cqv²Px ΔP: pressure loss(pa) qv: volume flow qm: mass flow ΔP=Cqm²Px PX: density C: constent |
Display | Two-line LCD display, four button operation Instantaneous flow, accumulated flow, vortex frequency, medium temperature, pressure(selectable), circular or non-circular display |
Power supply | Ordinary type: (14~36) VDC Ex-proof type: (14~30) VDC Battery power supply |
Loading | No-ex-proof: RB=(UB-14DVC)/22MA≤1200Ω Ex-proof: RB=(UB-14DVC)/22MA≤600Ω |
Output | Two wire 4~20mA |
Ex-proof class | Exd II CT6 CE19.1438 Ex ( ia ) II CT6 |
Cable interface | 1/2''NPT( Internal thread, recommended), M201.5 (Internal thread) |
Housing protection class | IP67 |
Connection type | Flange (DN15-DN300), Clamping (DN15-DN100) |
Mounting type | Integral mounting, split mounting (special shielded cable connect the pipe and indicator) |
Gas | |||
Air: t=20°C p=1.013bar abs =1.7210-4 mpa.s Q: flow (sheet 1) | |||
Nominal diameter | Internal diameter | Qmin(m3/h) | Qmax(m3/h) |
DN15 | 16 | 6.79 | 32.56 |
DN25 | 24 | 10.20 | 113.94 |
DN40 | 38 | 25.3 | 326.63 |
DN50 | 50 | 43.89 | 565.49 |
DN80 | 74 | 96.14 | 1238.64 |
DN100 | 97 | 165.14 | 2128.27 |
DN150 | 146 | 374.23 | 4821.57 |
DN200 | 193 | 702.95 | 9056.8 |
DN250 | 253 | 1123.7 | 14478 |
DN300 | 305 | 1632.1 | 21028 |
Liquid | |||
Water: t=20°C p=1.013bar abs ≤10cp Q: flow | |||
Nominal diameter | Internal diameter | Qmin(m3/h) | Qmax(m3/h) |
DN15 | 16 | 0.45 | 5 |
DN25 | 24 | 0.81 | 11.40 |
DN40 | 38 | 2.04 | 28.57 |
DN50 | 50 | 3.53 | 49.47 |
DN80 | 74 | 7.74 | 108.37 |
DN100 | 97 | 13.30 | 186.21 |
DN150 | 146 | 30.13 | 421.86 |
DN200 | 193 | 52.66 | 792.42 |
DN250 | 253 | 90.5 | 1266.8 |
DN300 | 305 | 113.41 | 1839.8 |
Saturated steam | |||||||||
Nominal Diameter |
Inner Diameter |
Mass flow Qm (kg/h) under different pressure and density | |||||||
P=1bar G | P=3.5bar G | P=5.2bar G | P=7 bar G | ||||||
ρ=1.13kg/m3 | ρ=2.43kg/m3 | ρ=3.28kg/m3 | ρ=4.17kg/m3 | ||||||
t=120.6°C | t=148.2°C | t=160.4°C | t=170.6°C | ||||||
min | max | min | max | min | max | min | max | ||
DN15 | 16 | 5.87 | 36.97 | 7.68 | 79 | 8.93 | 106.68 | 10.06 | 135.69 |
DN25 | 24 | 11.82 | 129.39 | 17.26 | 276.4 | 20.09 | 373.53 | 22.66 | 474.82 |
DN40 | 38 | 29.64 | 370.71 | 43.33 | 792.33 | 50.63 | 1070.2 | 56.8 | 1361.2 |
DN50 | 50 | 51.31 | 641.82 | 75.02 | 1371.8 | 87.19 | 1852.8 | 98.33 | 2356.6 |
DN80 | 74 | 112.41 | 1405.8 | 164.33 | 3004.7 | 191 | 4058.4 | 215.39 | 5161.8 |
DN100 | 97 | 193.14 | 2415.5 | 282.36 | 5162.7 | 328.16 | 6973.3 | 370.09 | 8869.2 |
DN150 | 146 | 437.56 | 5472.4 | 639.69 | 11696 | 743.45 | 15798 | 838.44 | 20093 |
DN200 | 193 | 821.91 | 10279 | 1201.6 | 21970 | 1396.5 | 29675 | 1574.9 | 37743 |
DN250 | 253 | 1313.9 | 16433 | 1920.9 | 35122 | 2232.5 | 47439 | 2517.7 | 60337 |
DN300 | 305 | 1908.3 | 23866 | 2789.8 | 51010 | 3242.4 | 68899 | 3656.6 | 87630 |
Nominal Diameter |
Inner Diameter |
Mass flow Qm (kg/h) under different pressure and density | |||||||
P=10.5 bar G | P=14 bar G | P=17.5 bar G | P=20 bar G | ||||||
ρ=5.89kg/m3 | ρ=7.6kg/m3 | ρ=9.32kg/m3 | ρ=10.54kg/m3 | ||||||
t=186.2°C | t=198.5°C | t=208.5°C | t=215.6°C | ||||||
min | max | min | max | min | max | min | max | ||
DN15 | 16 | 12.78 | 191.71 | 16.51 | 247.55 | 20.23 | 303.36 | 22.89 | 343.32 |
DN25 | 24 | 26.93 | 670.88 | 30.6 | 857.88 | 33.87 | 955.48 | 36.04 | 1201.41 |
DN40 | 38 | 67.51 | 1878.2 | 76.72 | 2150.7 | 84.93 | 2395.3 | 90.35 | 2557.7 |
DN50 | 50 | 116.89 | 3251.7 | 132.82 | 3723.4 | 147.03 | 4147 | 156.42 | 4428.1 |
DN80 | 74 | 256.03 | 7122.4 | 290.93 | 8155.8 | 322.06 | 9083.7 | 342.62 | 9699.3 |
DN100 | 97 | 439.91 | 12238 | 499.9 | 14013 | 553.38 | 15608 | 588.69 | 16666 |
DN150 | 146 | 996.62 | 27725 | 1132.5 | 31747 | 1253.7 | 35359 | 1333.7 | 37756 |
DN200 | 193 | 1872.1 | 52079 | 2127.3 | 59634 | 2354.9 | 66419 | 2505.2 | 70921 |
DN250 | 253 | 2992.7 | 83254 | 3400.71 | 95333 | 3764.6 | 106180 | 4004.9 | 113380 |
DN300 | 305 | 4346.5 | 120920 | 4939.1 | 138460 | 5467.5 | 154210 | 5816.5 | 164660 |
Selection list | ||||||||
model | Explanation | |||||||
ZZY30 | ||||||||
Connection | F | Flange connection | ||||||
W | Flange clamping | |||||||
Temperature Resistance Class |
T1 | Match with 250°c probe | ||||||
T2 | Match with 350°c probe | |||||||
Nominal diameter |
015 | DN15 | ||||||
020 | DN20 | |||||||
025 | DN25 | |||||||
032 | DN32 | |||||||
040 | DN40 | |||||||
050 | DN50 | |||||||
065 | DN65 | |||||||
080 | DN80 | |||||||
100 | DN100 | |||||||
125 | DN125 | |||||||
150 | DN150 | |||||||
200 | DN200 | |||||||
250 | DN250 | |||||||
300 | DN300 | |||||||
Structure |
Z | Integrated T and P compensation | ||||||
F | Regular model | |||||||
S | Split | |||||||
Material | R1 | 304 | ||||||
RL | 316L | |||||||
Instrument model |
N | 24V power supply Output 3 wire pulse | ||||||
V1 | 24V power, on-site display, 4-20mA, RS485, Impulse output | |||||||
V1 B |
24V +battery power supply, on-site display, 4-20 mA, RS485, pulse output | |||||||
Pressure Class | N | Normal | ||||||
H | High pressure |
PACKING & SHIPPING
We will deliver your ordered product at the earliest possible date, precisely as required.Installation Requirements
Piping Condition
For optimal performance, the installation of the vortex flowmeter necessitates specific straight pipe sections before and after the sensor. Here are the typical scenarios (D represents the pipe diameter):
Piping condition | upstream | Downstream |
Concentric shrinkage pipe full open gate valve |
15D | 5D |
∠90° square elbow | 20D | 5D |
Same plane 2∠90°elbow | 25D | 5D |
Semi-open gate valve regulating valve | 50D | 5D |
Different plane 2∠90°elbow | 40D | 5D |
With rectifier tube bundle | 12D | 5D |
1.
The sensor must be installed on a horizontal, vertical, or inclined pipe (with the liquid flowing from bottom to top) with the same diameter as the sensor. Ensure there are adequate straight sections of the pipe both upstream and downstream, typically 15-20D for the upstream and 5-10D for the downstream sections.
2.
The pipe near the liquid sensor must be completely filled with the liquid being measured.
3.
Avoid installing the sensor on pipes with strong mechanical vibrations.
4.
Maintain consistency between the inner diameter of the straight pipe section and the sensor diameter. If this isn't possible, use a slightly larger diameter pipe with a maximum error of ≤3% and not exceeding 5mm. Avoid installing the sensor in areas with strong electromagnetic interference, limited space, or inconvenient maintenance..
5.
Horizontal installation is most common for flow sensors. For gas flows containing minor liquid amounts, install the sensor at a higher point in the pipeline. For liquid flows with minor gas amounts, install the sensor at a lower point in the pipeline.
6.
For vertical pipelines, the sensor can be installed without flow direction constraints when measuring gas. For gas flows with minor liquid amounts, ensure the flow is from bottom to top. For liquid flows, the flow should be from bottom to top to prevent additional weight on the probe.
7.
Side-mounted sensors on horizontal pipelines are suitable for various fluids, including superheated steam, saturated steam, and low-temperature liquids. Side mounting is preferred when feasible, as it reduces temperature impact on the amplifier.
8.
Inverted sensor installation on horizontal pipelines is generally discouraged. It's unsuitable for measuring standard gases or superheated steam but can be used for saturated steam and high-temperature liquids, or in scenarios requiring frequent pipeline cleaning.
9.
When measuring high-temperature steam, ensure the insulation layer on the pipeline does not exceed one-third of the bracket height.
10.
Pressure and temperature measurement points: Position the pressure measurement point 3-5D downstream and the temperature measurement point 6-8D downstream from the sensor, depending on measurement requirements.