Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
We are committed to delivering your ordered product at the earliest date as per your requirements, ensuring timely and efficient service. Our logistics team coordinates seamlessly to guarantee that your Explosion Proof Flowmeter reaches you without delay, maintaining the highest standards of safety and care throughout the delivery process.The installation of the electromagnetic flowmeter is tailored to accommodate the site-specific pipeline conditions. For flowmeters that do not incorporate a ball valve, they should be installed on a non-pressurized pipeline. This non-pressurized installation allows for the selection of flowmeters without the necessity of a ball valve.
A hole with a diameter of 50mm must be created in the pipeline, and preparations should be made to weld a connecting pipe to the opening in the pipeline.
In scenarios requiring continuous fluid flow during loading and unloading, or where preventing media overflow is crucial, a ball valve must be incorporated. This necessitates selecting an insertion-type electromagnetic flowmeter equipped with a ball valve structure.
A hole with a diameter of 50mm must be created in the pipeline, and preparations should be made to weld a connecting pipe to the opening in the pipeline.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
To ensure optimal performance and accuracy of the electromagnetic flowmeter, the straight pipe sections should adhere to a length of 5D upstream and 3D downstream.
The measurement principle of the electromagnetic flowmeter is independent of the flow's characteristics, ensuring reliable operation under varied conditions.
Even if turbulence and vortices are generated in the non-measurement area of the pipeline (such as due to elbows, tangential throttles, or partially open shut-off valves upstream), they will not impact the measurement.
However, if steady-state vortices form within the measurement area, it will compromise the stability and accuracy of the readings.
In such cases, measures should be taken to stabilize the flow distribution:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To mitigate the effects of vortices and flow field distortions, specific lengths for the upstream and downstream straight pipe sections of the flowmeter are required. Failure to meet these requirements can affect measurement accuracy (a straightener can be installed, and it is advisable to avoid installation near control valves and partially open valves).
2.2. Requirements for the Process Pipes The upstream and downstream process pipes at the installation point must meet specific criteria to ensure accurate measurements: a. The inner diameters of the upstream and downstream process pipes must match that of the sensor and comply with the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the inner diameter of the sensor, and D is the inner diameter of the process pipe). b. The process pipe and the sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes: To ensure the seamless maintenance and optimal performance of the flowmeter, it is highly recommended to install a bypass pipe. This is particularly essential for scenarios involving heavily contaminated fluids or when it's necessary to clean the flowmeter without halting fluid flow. a. Facilitates efficient maintenance of the flowmeter. b. Crucial for managing heavily contaminated fluids. c. Enables cleaning of the flowmeter without interrupting fluid flow.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters: Comprehensive guidelines ensure the optimal functioning and performance of insertion-type electromagnetic flowmeters.
3.1. Requirements for Straight Pipe Sections: To maintain precise readings and performance, the following inlet/outlet straight pipe sections are essential: Inlet should be ≥ 10×DN; Outlet should be ≥ 5×DN.
3.2. Requirements for Grounding Points: To guarantee reliable operation and enhanced measurement accuracy, the sensor must be well-grounded to avoid external parasitic potentials. The grounding resistance should be less than 10. (A dedicated grounding device is unnecessary if the metal pipeline is adequately grounded.)
3.3. Requirements for Installation Position: For optimal results, please refer to the installation position as depicted in the accompanying diagram.
COMPANY AND FACTORY PICTURE: A visual tour of Shandong Zhongziyi Intelligent Technology Co., Ltd., showcasing our advanced facilities and cutting-edge technologies.