Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
We are dedicated to providing swift, efficient delivery of your ordered products, ensuring they arrive as promptly as your needs dictate, all while maintaining impeccable service standards.The installation of the electromagnetic flowmeter is tailored to the specific site pipeline conditions. Flowmeters without a ball valve should be installed on non-pressurized pipelines. This allows for the selection of flowmeters without the necessity of a ball valve, ensuring a smoother installation process.
A hole with a diameter of 50 mm should be created in the pipeline, followed by welding a connecting pipe to this opening. This step is crucial for a secure and accurate installation.
For scenarios requiring continuous flow during loading/unloading or where media overflow must be prevented, a ball valve is essential. In such cases, an insertion-type electromagnetic flowmeter with a ball valve structure should be employed.
A hole with a diameter of 50 mm should be drilled into the pipeline, and a connecting pipe should be welded to this opening to prepare for the flowmeter installation.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
To ensure the proper functioning and accuracy of the electromagnetic flowmeter, the straight pipe sections should be 5D upstream and 3D downstream. This alignment meets the necessary accuracy requirements.
The measurement principle of the electromagnetic flowmeter is independent of the flow's characteristics, ensuring reliable readings under various conditions.
Turbulence and vortices in non-measurement areas (like elbows, tangential throttles, or partially open shut-off valves upstream) do not affect the measurement, ensuring dependable results.
However, steady-state vortices within the measurement area can impact measurement stability and accuracy. This must be avoided for precise readings.
To stabilize the flow distribution when steady-state vortices are present, several measures can be adopted:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To reduce vortices and flow field distortion, specific lengths for the straight pipe sections upstream and downstream of the flowmeter are necessary. Without this, measurement accuracy will be compromised. Consider using a flow straightener and avoid installing close to control or partially open valves.
2.2. Requirements for Process Pipes The flowmeter has precise requirements for upstream and downstream process pipes at the installation site. The inner diameter of these pipes should match the sensor's diameter: 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter). Additionally, the process pipe and sensor must be concentric, with an axial deviation not exceeding 0.05DN, ensuring measurement precision.
2.3. Requirements for Bypass Pipes To ensure the utmost convenience in maintaining your flowmeter, the installation of a bypass pipe is highly recommended. This is particularly crucial for handling heavily contaminated fluids and scenarios where the flowmeter needs to be cleaned without interrupting the fluid flow. a. Simplifies the maintenance process of the flowmeter. b. Essential for handling heavily contaminated fluids. c. Allows uninterrupted fluid flow during cleaning procedures.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections Inlet and outlet straight pipe sections: To optimize performance, the inlet section should be at least 10 times the diameter of the pipe (≥ 10×DN), while the outlet section should be no less than 5 times the diameter of the pipe (≥ 5×DN).
3.2. Requirements for Grounding Points To guarantee the reliable operation of your flowmeter and enhance measurement accuracy, it must be shielded from external parasitic potentials. Ensure the sensor is properly grounded, maintaining a grounding resistance of less than 10 ohms. (Note: If the metal pipeline is already well-grounded, a dedicated grounding device is unnecessary.)
3.3. Requirements for Installation Position Refer to the accompanying diagram for precise installation positioning.