Product advantages | ||
Project | CAMCT | Others |
Lower flow limit | 0.1m/ s (linear accuracy guaranteed) |
0.3m/ s (linear accuracy guaranteed) |
Response time | 100ms | ≥3S |
Strong steady flow function | have | Don't have |
Product category | |||
Medium | Conductive liquid such as sewage, chemical liquid and tap water | ||
Output | 4-20Ma (load resistance 0~750Ω), pulse, frequency, RS485 protocol | ||
Accuracy class | Class 0.3, 0.5 | Velocity range | 0.1-15m/ s |
Medium temperature | -20~+160ºC | Ex-proof grade | Exd lI CT6 G |
Protection grade | IP67, Special requirements could up to IP68 |
Technical parameters | |
Executive standards | Electromagnetic flowmeter(JJG 1033-2) |
Nominal caliber (can be customized) | Pipe type PTFE lining: DN15-DN2000 Pipe type rubber lining: DN65-DN2000 Pipe type PFA lining: DN40-DN600 |
Flow direction | Positive, negative, net flow |
Range down | 150:1 |
Repeatability | ±0.1% |
Medium temperature | Regular rubber lining: -20ºC~+60ºC Normal temperature rubber lining: -20ºC~+90ºC PTFE lining: -30ºC~+120ºC High temperature PFA lining: -20ºC~+160ºC |
Rated working pressure | (DN15~DN25) ≤4.0MPa (DN32~DN300)≤1.6MPa (DN350~DN800)≤1.0MPa (DN800~DN2000)≤0.6MPa |
Velocity range | 0.1-15m/ s |
Conductivity range | ≥5μ s / cm |
Communication output | RS485, HART protocol, GPRS output |
Power supply | 220VAC,Tolerance 15%or 24VDC,ripple wave≤5% |
Required straight pipe segment length | Upstream≥5DN, Downstream≥2DN |
Connection type | Flange connection: HG20592-2015 |
Protection grade | IP67 |
Ex-proof Class | ExdIIct6 Certificate No.:CE19.14 |
Ambient temperature | -25°ºC~+60°ºC |
Relative humidity | 5%~95% |
Total power consumed | <7.5W |
Measurable range | |||||
Caliber | Min adjustable range(0.3m/s, per hour) | Max adjustable range (10m/s, per hour) |
|||
mm | inch | m³/h | GPM | m³/h | G |
15 | 0.5 | 0.19 | 0.84 | 6.36 | 28.0 |
25 | 1 | 0.53 | 2.35 | 17.7 | 78.0 |
32 | 1.25 | 0.87 | 3 | 29.0 | 100 |
40 | 2 | 1.36 | 600 | 45.2 | 200 |
50 | 2 | 2.12 | 9.35 | 70.7 | 310 |
65 | 2.5 | 3.58 | 15.0 | 119.5 | 502 |
80 | 3 | 5.43 | 24.0 | 181.0 | 800 |
100 | 4 | 8.48 | 37.5 | 282.7 | 1250 |
125 | 5 | 13.25 | 60.2 | 441.8 | 2008 |
150 | 6 | 19.1 | 84.0 | 636.1 | 2800 |
200 | 8 | 34.0 | 150.0 | 11313 | 5000 |
250 | 10 | 53.0 | 41.0 | 1767 | 8031 |
300 | 12 | 76.3 | 347 | 2544 | 11565 |
350 | 14 | 103.9 | 472.3 | 3463 | 15741 |
400 | 16 | 135.7 | 616.9 | 4523 | 20560 |
Selection list | ||||||
ZYDC | Intelligent electromagnetic flowmeter | |||||
M | Integral | |||||
F | Split | |||||
Lining material | F | PTFE | ||||
Z | Rubber lining | |||||
A | PFA | |||||
Pipe connection | C1 | HG 1.0Mpa flange type | ||||
C2 | HG 1.6Mpa flange type | |||||
C3 | HG 2.5Mpa flange type | |||||
E1S | DIN PN10 clamping type | |||||
E2S | DIN PN16 clamping type | |||||
Instrument caliber | DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 | |||||
Nominal caliber | ||||||
Electrode material | L | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
N | No | |||||
Electrode ring | S | 316L | ||||
H | HC 276 | |||||
Ti | Titanium | |||||
Ta | Tantalum | |||||
P | Platinum-iridium alloy | |||||
Connection | ||||||
2 | 1/2" NPT Internal thread | |||||
4 | M20*1.5 Internal thread | |||||
Power supply | A2 | 220V AC | ||||
D1 | 24V DC | |||||
Ex-proof | Explosion-proof sign | |||||
N | No ex-proof | |||||
D | Flame-proof EXD II CT6 | |||||
Communication protocol | Communication protocol | |||||
N | No | |||||
H | Hart protocol | |||||
M | Modbus protocol | |||||
P | Profibus-PA | |||||
Selection example: ZYDC/M/F/C2/L/DN25 | ||||||
Explanation: intellgiengt flowmeter integrated PTFE lining flange connection 1.6Mpa 316L electrode 1/2NPT internal thread 220V AC power supply Modbus protocol |
PACKING & SHIPPING
At Shandong Zhongziyi Intelligent Technology Co., Ltd., we prioritize your needs and are committed to delivering your ordered High Accuracy Flowmeter with Wireless Transmission and Explosion Proof Features at the earliest convenience. Our dedicated team ensures a seamless and efficient service, guaranteeing timely delivery that meets your specifications and expectations.The installation of the electromagnetic flowmeter varies depending on the site pipeline conditions. Flowmeters without a ball valve should be installed on a non-pressurized pipeline (i.e., non-pressurized installation allows for the selection of flowmeters without a ball valve).
A precise hole with a diameter of 50mm should be made in the pipeline, and preparations should be undertaken to weld a connecting pipe to the opening in the pipeline.
For situations that require continuous flow during loading and unloading or where media overflow is not permitted, a ball valve must be added. This necessitates selecting an insertion-type electromagnetic flowmeter equipped with a ball valve structure.
A precise hole with a diameter of 50mm should be made in the pipeline, and preparations should be undertaken to weld a connecting pipe to the opening in the pipeline.
Measuring range | Recommend using range | 0.5m/s to 10m/s continuously adjustable |
Max using range | 0.2m/s ~ 15m/s continuously adjustable |
|
Output | The switching quantity can be set to | Pulse output (up to 1000HZ) |
High/low flow alarm | ||
Empty pipe alarm | ||
Flow direction indication | ||
Fault alarm | ||
Current output | Output 4-20mA | |
Configuration mode | Field configuration with three manual keys | |
Field configuration through remote controller | ||
Field configuration by hand operator | ||
Memory | EEPROM memory that does not disappear and does not require battery storage |
To ensure proper use and meet accuracy requirements, the straight pipe sections must be 5D upstream and 3D downstream.
The electromagnetic flowmeter's measurement principle is unaffected by the flow characteristics.
Should there be turbulence and vortices generated in the non-measurement area of the pipeline (such as elbows, tangential throttling, or a partially open shut-off valve upstream), it will not impact the measurement.
However, if steady-state vortices occur in the measurement area, it will affect both stability and accuracy.
In such cases, measures should be enacted to stabilize the flow distribution:
1.2. Pipeline-type Electromagnetic Flowmeter
2.1. Requirements for Straight Sections To mitigate the effects of vortices and flow field distortion, there are specific requirements for the lengths of straight pipe sections upstream and downstream of the flowmeter. Failure to meet these requirements will affect measurement accuracy (a flow straightener can also be installed, and it is advisable to avoid installation close to control valves and partially open valves).
2.2. Requirements for Process Pipes The flowmeter has specific requirements for the upstream and downstream process pipes at the installation point; otherwise, measurement accuracy will be affected. a. The inner diameter of the upstream and downstream process pipes should match the sensor's inner diameter, and must meet the condition: 0.98DN ≤ D ≤ 1.05DN (where DN is the sensor's inner diameter, and D is the process pipe's inner diameter). b. The process pipe and the sensor must be concentric, with an axial deviation not exceeding 0.05DN.
2.3. Requirements for Bypass Pipes To ensure seamless maintenance of your flowmeter, it is strongly recommended to install a bypass pipe. This becomes crucial for systems dealing with heavily contaminated fluids, enabling cleaning and maintenance without interrupting fluid flow. a. Facilitates easy maintenance of the flowmeter. b. Essential for handling heavily contaminated fluids. c. Allows for uninterrupted fluid flow during cleaning operations.
3. Installation Requirements for Insertion-Type Electromagnetic Flowmeters
3.1. Requirements for Straight Pipe Sections To achieve optimal performance, the insertion-type electromagnetic flowmeter requires specific straight pipe sections: the inlet should extend ≥ 10×DN and the outlet should extend ≥ 5×DN.
3.2. Grounding Point Requirements For unparalleled accuracy and reliable operation, the flowmeter must be properly grounded to avoid external parasitic potentials. The sensor should be grounded with a resistance of less than 10 ohms. (If the metal pipeline is already well-grounded, a dedicated grounding device is not necessary.)
3.3. Installation Position Requirements Refer to the accompanying diagram for precise installation positioning.